model-no-ddu-100a

Model No. DDU 100A

95,000.00

Technical Specifications

Defibrillator

  • Type Semi-automatic external defibrillator
  • Energy Adult:150 Joules Pediatric: 50 Joules [Nominal into 50 Ohm load]
  • Charge Time Lessthan 6 to 9 seconds
  • Voice Prompts Extensive voice prompts guide user through operation ofthe unit and CPR
  • Cpr Pacing Metronome
  • Controls Lighted On/Off button Lighted Shock button
  • Indicators “check pads” “d0 not touch patient” analyzing” AED Status LED

Defibrillation / Monitoring Pads

  • Model Adult— DDP— 100 Child/Infant—DDP—ZUOP
  • Type Pre-connected,single-use,non-polarized, disposable,self-adheswe electrodeSWIth cable and connector
  • Surfalnce Area 103 cm2[nom|nal, each pad]50 cm2 [nommaL each pad]
  • Pad Placement Adult — Anterior/Anterior Child/Infant —Anterior/Posterior
  • Cable Length [typical] 48″ [122 cm]

Event Documentation

  • Internal Event Record Critical ECG segments and – Easy and Convenient operation rescue event parameters are recorded and can be – High-fidelity. crystal clear sound
    downloaded to a removable data card
  • Earphone and speaker are feasible
  • Pc-based Event Review Ecg with eventtag display, and audio when available
  • Removable Storage {optional} Up to 12 hours of ECG and event data storage[no audio optionlorupt02 hours ofaudio, ECG and event storageIaudio optionlonaremovable data card.Actual length of storage is dependenton card capacity

Patient Analysis System

  • Patient Analysis Automatically evaluates patient impedance for proper pad contact. Monitors signal qualityand analyzes patient ECG forshockable/non-shockable rhythms
  • Sensitivity/specificity Meets AAMI—DF—39 specifications and AHA recommendations

Battery Pack

  • POWER15V, 2800 mAh/1400mAh
  • CAPACITY 300 shocks or 1 6 hours continuous operation**
  • STANDBY LIFE 7 or 5years
  • TYPE Lithium/Manganese Dioxide Disposable. recyclable, non-rechargeable
  • LOW BATTERY INDICATORS Visible Audible

Self Tests

  • AUTOMATIC Automatic Automatic daily,weekly, monthly and quarterly circuitry tests
  • BATTERY INSERTION System integrity test
  • PAD PRESENCE Pads preconnected tested daily
  • USER-INITIATED Unit and battery pack systemtest may also be Initiated bythe user
  • STATUSINDICATION Visual and audible indicationofunit status

Physical

  • Size : 8.5×11.8×2.7inches
  • Weight : [ApproximateIWith 4.4lbsl2.0 kg]
Categories: ,

Reviews

There are no reviews yet.

Be the first to review “Model No. DDU 100A”

Your email address will not be published. Required fields are marked *