modelnofm-201

Model No. FM 201

Technical Features:

  • Power Supply; AC: 100~240V,50/60 Hz & DC: 14.8V/2200mAh
  • Working Time [on Battery] 2 Hrs
  • Recorder[Built in]
    • Method : Thermal Printer
    • Paper : Z-fold, thermo sensitive
    • Paper Width : 110 mm [4.33 inch] /150 mm [5.91 inch]
    • Printing speed : 1/2/3 cm/min | Trace: Max 4tracks
    • Recording way : Real—time Recording and review printing
  • Alarm
    • Low, Medium and High Auditory, Visual and delayin FHR
    • alarm, Ultrasound [FHR]
    • TransducerType : 12-Crystal ultrasound trasducer
    • Measure method : Wide beam pulse Doppler
    • FHR measurement range : 30 ~ 240bpm
    • Accuracy : ±1bpm Intensity : < 3 mW/cm2
    • Ultra sound Frequency : 1MHz ±3%
    • Resolution : 1bpm

TOCO

  • Measurement Method : Strain gauge sensor element
  • Measurement range : 0 ~ 100 units Resolution: 1 unit
  • Non linear deviation: < ±8%
  • Baseline setting : 0.5, 10, 15, 20 can be selected
  • Auto offset correction : 3 second after connecting the transducer
  • Auto zero adjust : TOCO value is set to zero negative following a negative measure value for 5 seconds

Fetal Movement Recording

  • Automatic fetal movement [AFM]: pulsed Doppler ultrasound Automatic fetal movement autograph Manual fetal movement marker [MFM]

ECG

  • Lead Mode : 3/5 leads [I, II, III or I, II, III, aVR, aVL, aVF, V]
  • Gain : 2.5, 5, 10, 20, 40 mm/mV and AUTO
  • Accuracy: ±1bpm or ±1% [whichever is greater]
  • Resolution : 1bpm
  • Leakage Current : < 10pA
  • CMRR : Diagnostic Mode: > 89 dB, Monitor Mode: >105 dB
  • Surgery Mode : > 105 dB
  • Bandwidth : 0.05 ~ 120 Hz

Heart Rate

  • Measurement Range-Adult : 10 ~ 300 bpm
  • Neonate : 10 ~ 350 bpm
  • Resolution : 1 bpm
  • Accuracy : ±1bpm or ±1% [whichever is greater]

ST Segment Measurement

  • Range : -2 ~ +2 mV
  • Resolution : 0.01mV
  • Accuracy : -0.8mV ~ +0.8mV; ±0.02mV or 10% [whichever is greater] Other range : Unspecified

Respiration

  • Method : Impedance between RA-LL, RA-LA
  • Gain : 0.25, 0.5, 1, 2, 4
  • Resolution : 1 bpm
  • Respiration Rate : 0 bpm; 6 ~ 150 bpm
  • Accuracy : 12 bpm or ±2%, [whicheveris greater]
  • Apnea Alarm : 10 ~ 60 s

Sp02 [Digital Technology]

  • Measurement Range : 0 ~ 100%
  • Resolution : 1%
  • Accuracy :
  • ±2% [70% ~ 100%]
  • ±3% [35% ~ 69%]
  • Unspecified [0% ~ 34%]

Pulse Rate

  • Range : 25 ~ 250bpm
  • Accuracy : ±1% or ±1 bpm, [whichever is greater]
  • Resolution : 1bpm

Maternal NIBP [MNIBP]

  • Method : Oscillometric
  • Measure mode : Manual, Auto and STAT Measure interval in AUTO Mode 1 ~ 480 min
  • STAT mode cycle time: Keep 5 mins, at 5 seconds interval
  • Measure and Alarm Range : Systolic: 30 ~ 270 mmHg, Diastolic : 10 ~ 220 mmHg,
  • Mean : 20 ~ 235 mmHg
  • Static pressure accuracy : 13 mmHg
  • Resolution : 1 mmHg
  • Over Pressure Protection : Dual protection via Software and Hardware

Temperature

  • Technique : Thermistor probe [2.25K] Measuring and Alarm Range: 0.0°C ~ 50°C [32°F ~ 122°F]
  • Unit : Celsius [°C] and Fahrenheit [°F] Resolution : 0.1 °C
  • Accuracy : ±0.1°C

OPTIONAL: 10″ display, Dual FHR, Touch Screen, Keyboard, Mouse, Central Monitoring System, HDMI, Fetal Simulator, Waterproof probe, Wall mount stand, Trolley and Fischer NST Report